The fourth and shallowest zone at Inanli-1 was tested at a flow rate of 0.306 mmcf/d averaged over a period of ten days from a 37.6 m gross section. The rate for the final 24 hours of flow was 0.171 mmcf/d. The condensate yield was 23 bbl/mmcf over the total flowing period, but this was increasing over the course of the test and during the final 24 hours the rate was 97 bbl/mmcf. Water recovery was 98 bbl/d over the final 24 hours of flow and was declining. The flow results of the fourth test

21 Oct 2019
FLASH: Final well test results at Inanli-1 - Equinor will start testing Devepinar-1

Sign up to access
Get access to our full offering from over 30 providers
Get access to our full offering from over 30 providers
FLASH: Final well test results at Inanli-1 - Equinor will start testing Devepinar-1
The fourth and shallowest zone at Inanli-1 was tested at a flow rate of 0.306 mmcf/d averaged over a period of ten days from a 37.6 m gross section. The rate for the final 24 hours of flow was 0.171 mmcf/d. The condensate yield was 23 bbl/mmcf over the total flowing period, but this was increasing over the course of the test and during the final 24 hours the rate was 97 bbl/mmcf. Water recovery was 98 bbl/d over the final 24 hours of flow and was declining. The flow results of the fourth test